NEC 2011 Transformer Secondary Conductors 240.21(C)(6) (10min:42sec) siavash533 694 مشاهده

4055

Section 240.21 contains tap conductor rules and states overcurrent protection shall be provided in each ungrounded circuit conductor and shall be located where the conductors receive theirsupply except as specified in 240.21(A) through (H), which covers branch-circuit taps, feeder taps, transformer secondary conductors, service conductors, busway taps, motor-circuit taps, conductors from

240.21(B)(1) Feeder Taps Not over 3 m (10 ft) Long. Click to Enlarge The tap conductor ampacity cannot be less than the rating of the equipment containing an overcurrent device supplied by the tap conductors or not less than the rating of the overcurrent … 240.21(B) Feeder Taps. Conductors shall be permitted to be tapped, without overcurrent protection at the tap, to a feeder as specified in 240.21(B)(1) through (B)(5). The tap shall be permitted at any point on the load side of the feeder overcurrent protective device. Section 240.4(B) shall … NEC 2014 edition electrical code tap rules The NEC article dealing with overcurrent protection of feeder taps is article 240.21(B).

Nec 240.21

  1. Vilopuls 13 åring
  2. Bearbeta trauma från barndomen
  3. K2a b aktie

New item 1 added as condition as one of the conditions that must be met in  Apr 1, 2014 Question 20: 240.21(C)(1)(2)&(3) Transformer Secondary Conductors. Question ID#: 2479. Overcurrent protection on the secondary side of a  Our electrician was using some sections of part II of art 240.21(B) feeder taps, to approve the configuration of non service entrance rated  NEC 240.21 Location in Circuit. Overcurrent protection shall be provided in each ungrounded circuit conductor and shall be located at the point where.

240.21(B) Feeder Taps. ○ Conductors shall be permitted to be tapped, without overcurrent protection at the tap, to a feeder as specified in. 240.21(B)(1) through  

(NEC 300.6 C1, 310.8 D). Master The NEC Enjoy this graphic on Transformer Secondary Conductor rules in 240.21(C)(6). P.S.- If you do not like itLOL..Make Your Own!.. Feeder Taps, NEC 2011 - 240.21(B)(1) (13min:22sec) · Electrical Feeder and Branch circuit description · Follow Electricity's Journey Through the Transmission   [240.21(C)(2)] characteristics and appropriate NEC® sections should be considered.

There was a change to 240.21(C)(3) in the 2014 NEC. Before the 2014 edition, this section started with, “For industrial installations only … .” Now, this section starts with, “For the supply of switchgear or switchboards in industrial installations only .” This was not really a change, but a clarification.

visningar 144tn. NEC 2014 - Appliance GFCI Protection [422.5].

I bring up these three points because it’s easy to become so involved in the “location” rules (240.21) that you may misinterpret them into meaning that secondary conductor overcurrent protection is not required at all! Battery conductors, for which you install the OCPDs as close as practicable to the battery terminals 240.21 (H)]. OCPDs must be readily accessible [240.24 (A)]. Install them so the center of the grip of the operating handle, when in its highest position, isn’t more than 6 ft, 7 in. above the floor or working platform. was added to 240.21(C) in the 2005 code cycle, but that was not a code change. The rule has always specified that the conductor have a specific ampacity.
Pollicis longus tendon pain

NEC 240.24(B) present in NEC Section 240-21 based upon distance. Conclusion: Proper panelboard protection and application is essential to electrical distribution system design.

1. NEC 430.53 (A) addresses installations where all of the motors are rated 1 hp or less. 2.
Mina spår







2008-01-31

Is a service receptacle required in a furnace room located in the middle of a  24 Aug 2016 NEC Code Making Process Where to Keep Abreast of the Latest NEC Information 240.21(B)(4) Applies to High Bay Manufacturing Areas  The National Electrical Code Article 240-21 details specific tap rules that should be considered before installation. NEC 240.21 Location in Circuit. Over current  240.21 Location in Circuit. Overcurrent Protection shall be provided in each ungrounded circuit conductor and shall be located at the point where the conductors  2. In applications of 600 V or less, overcurrent protection is typically located at the load end of the field installed conductors, NEC 240.21(C). (or Part VIII of Article  (NEC 240.21 B). 18. Provide a note stating that any conductors exposed to sunlight shall be listed as sunlight resistant.